MACRO - Macro Execution/Reporting
This command executes a specified macro or reports the last macro executed. There
are 255 macros that can be specified.
Command form: DEVICE
MACRO
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
MACRO Command form
Value 1-255 Value to execute user macros
Example:
#55 MACRO 1
On XAP 800 unit 5 (
#55
), Macro (
MACRO
)
1
is run.
MASTER - Expansion Bus Master Mode
This command reports the mode of the unit. The mode can be Master or Slave.
Command form: DEVICE
MASTER
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
MASTER Command form
Value 1 = Master, 2 = Slave, Null = Current mode of the unit
Example:
#56 MASTER 2
On XAP 800 unit 6 (
#56
), the
MASTER
mode is
set to slave (
2
)
MAX - Maximum Gain Setting
This command changes or reports back the maximum gain setting for an input,
output or assignable processing block.
Command form: DEVICE
MAX
<Channel> <Group> [Value]
Argument details
Name Description Units
Device 0–7 or * to select all units
MAX Command form
Channel See Groups and Channels, page 97
Group I, O, M, P, L
Value -65.00 to 20.00 dB
Null to return the current setting
Example:
#51 MAX 2 M 10
On XAP 800 unit 1 (
#51
), the maximum (
MAX
)
relative gain setting for mic (
M
) channel
2
is
10
dB.
114
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices ~ Appendix E: Serial Commands
The response indicates
execution of the macro,
but does not indicate that
each command within the macro
was executed.
This setting will affect all
relative gain adjustments.
Vista de página 119
1 2 ... 115 116 117 118 119 120 121 122 123 124 125 ... 148 149

Comentários a estes Manuais

Sem comentários